Part Number: ETI0001-2275
Extreme Environment
2000 VA UPS
Fixed Mount or Rackmount
2 kVA
Extreme UPS® w/
Input PFC, Manual Bypass and Self Test
Used in Extreme
Temperature Environments including
Outdoor Shelters and Switchgear
Applications
Supports Computers and Harsh Inductive Loads at the
Same Time
Rugged
Fixed Mount or Rackmount Unit

ETI0001-2275 Rugged MilSpec UPS Standard Front Panel Layout

ETI0001-2275 Rugged
MilSpec UPS Standard I/O Panel Layout
The
field proven Extreme UPS® line is ideally suited for industrial,
military, computer and telecommunications applications
requiring high reliability, rugged construction, compact size and light weight
design. These units are equally suited for use in locations with controlled or
uncontrolled environments including fixed,
field deployed, vehicular, shipboard or
airborne. For example, thousands of "ETI0001-2275"
units are being used
in the switchgear of wind turbine generators around the
world. In this application, the output
supports both a computer type load and operates large inductive switchgear contactors
at the same time. This places extreme demands in electrical performance
that causes most other vendors' UPS products to
fail. In the case of the
ETI0001-2275, it is able to
provide the large surge currents required to operate the contactors without
dropping the voltage and loosing the computer load!! On top of this, the
equipment operates in harsh temperature environment ranging from as low as
-40° Fahrenheit
(-40° Celsius) to
as high as 149°
Fahrenheit (65° Celsius).
The heavy-duty chassis, occupying minimal space while
delivering up to 2000 VA of clean, uninterruptible power. The
rounded metal corners and rugged handles, aid in safe handling. Internally, all major components are well
secured and electrically insulated to prevent damage due to shock and
vibration. These units can be mounted
horizontally or vertically. Optional heavy-duty rack slides provide
easy installation and removal of the unit with full extension.
The internal shielded input transformer
provides galvanic isolation with provisions for both domestic
(115 VAC, CONUS) and international (230 VAC, OCONUS) input voltages. The
optional autoranging input voltage selection allows inputting either 115 VAC or 230 VAC
without having to open the UPS enclosure.
These units work equally well from all AC sources including
poorly regulated generators. Special EMI/RFI filters and input
power factor correction minimize both input current and harmonics.
The unit also operates as a frequency converter, taking 46-70 hertz input and
converting it to clean, uninterruptible 60 hertz power. The input switch and the
galvanic isolation transformer all provide a double pole isolated source
for shipboard systems or overseas locations where phase references and grounding
are not always consistent. The nominal 120 VAC, 60 hertz output can be field set for 100, 110 or 115 VAC.
An alternate
version is also available for 200-240 VAC, 50 hertz output.
All controls and
protective devices are brought to the outer panels
with critical switches
or circuit breakers
having finger guards. Further, all critical devices
have finger guards to prevent damage or accidental
operation. The LED arrays keep the operator
informed as to the unit's status including load and battery levels.
The high intensity audible alarm can be heard in high noise environments.
The internal intelligent thermal sensors provide monitoring of unit
temperatures. The optional Elapsed
Time Indicator records the number of operational hours for records and
scheduling preventative maintenance of attached equipment. The front panel also
provides easy access to both the AC Input circuit breaker
and Battery Input fuse. Coupled with
the onboard spare fuse, MTTR is reduced to less than 15 minutes.
The
input circuit breaker and the galvanic isolation transformer
all provide a double pole isolated source for all installations including shipboard systems or
overseas locations where phase references and grounding are not consistent. The
manual bypass feature included is operated from the front panel. Even in the
bypass mode, the ETI0001-2275
still
provides galvanic isolation, transient surge protection and EMI/RFI filtering.
The unit also has a self test feature that can be initiated by the operator from
the front panel.
The
ETI0001-2275
has the added benefit of
having a
field replaceable battery tray. Even with this battery
tray removed, this UPS can continue to operate as an electronic power
conditioner and frequency converter, providing clean, well regulated, sinusoidal
power to the load.
The batteries are maintenance free with immobilized electrolyte and are
constructed of flame retardant materials for added safety. For more information, see the Battery
Technology section.
Removable and
washable air filters and a high capacity stainless steel ball bearing fans
provide added protection in both controlled and hostile environments. This
unit draws air through the intake filters and exhausts out the rear
or side vents.
This allows the unit to be used in negative or neutral pressure racks. For
positive pressure systems, other versions are available. The removable and washable metal screen air filters and high capacity
stainless steel ball bearing fans provide
added protection in both controlled and hostile environments.
The
I/O panel provides locking connectors for the
input and output power. Multiple input and output power panel options are
available. The exhaust air is diverted out the rear vent, with alternate air
flow directions optional. See the Power Distribution Units section for a
listing of stand alone PDUs. See the N5 Series section for
versions of UPS with an integrated PDU and remote control.
The
Status connector provides an interface with optional
computer
software providing loss of AC and low battery status as well as
remote shut down capability.
Overall, the Extreme UPS®
line is uniquely qualified for critical land based,
shipboard, vehicle or airborne systems combining advanced modular design
features with highly reliable construction.
Technical Specifications:
P/N:
ETI0001-2275
| AC
OUTPUT |
| Output voltage: |
Nominal 120 VAC true sinewave output standard,
optional 220 VAC version |
| Output voltage
adjustment: |
Can be set for 100, 110, 115 or 120 VAC via DIP switches |
| Output rating: UPS |
2000 VA,
1400 watts standard
Available in 1000,
1500, 2000 and 3000 VA ratings |
| Non-linear load
capacity: UPS |
Up to 100%
non-linear load capability w/o derating |
| Output voltage
regulation: UPS |
± 3.0% static
regulation of nominal
± 4.0% dynamic (0 to 50% load step) |
| Overload surge
capacity: UPS |
110% for 10 minutes;
125% for 30 seconds |
| Harmonic distortion:
UPS |
Less than 5.0% into
100% non-linear load |
| Output frequency:
UPS |
60 Hz ± 2.5%
synchronized to utility
60 Hz ± 1.0% w/ utility not available
50 Hz output available as an option |
| Operational status |
AC Input
status, UPS operational, UPS alarm, Battery level, Low battery, Load level,
Overload and Manual bypass LEDs,
Alarm contacts for Loss of AC and Low Battery
+90 dB audible alarm with audible on/off switch
Asynchronous serial COM port, optional SNMP/HTTP and
Elapsed Time Indicator |
| AC
INPUT |
| Input voltage
selection: |
Autoranging from nominal 115 VAC to 230 VAC |
| Input voltage
tolerance: UPS |
+15% -25%, or 85-135
and 170-270
@ full load without using battery, to 70 VAC @ 75% load |
| Input frequency: |
From 46 Hz to 70 Hz
standard, optional to 440 Hz |
| Input power factor: |
Better than 95%
typically |
| Input/output
isolation: |
2000 VA, up to 120 dB common mode, <1.0 mA leakage |
| Input transient
suppression: |
Complies with IEEE
587, UL 1449 and Mil Std 1399 |
| Input
control/protection: |
Guarded 2 pole
100 G shock rated circuit breaker (CB1)
Manual bypass switch to force bypass mode
Optional cold start switch available to turn on w/o AC present |
| Input power
connections: |
One
(1) AMP CPC, 3 pin, locking |
|
INTERNAL BATTERY |
| Internal |
Maintenance free
immobilized electrolyte,
Flame retardant materials (Oxygen Index 28+) |
| Internal |
Rated for continuous
service life of 5 years |
| Internal |
Front panel mounted
fuse (F1), spare fuse on front |
| Internal battery
time: |
15+ minutes @
full load
30+ minutes at 50% load |
| Internal battery
recharge: |
Recharged to nominal
in <8 hours |
| Internal battery
replacement: |
Battery module
tray from top of unit
<30 minutes to change battery modules |
| Battery expansion: |
Up to 24 hours w/
optional Battery Expansion Modules |
|
DISTRIBUTION PANEL |
| Output circuits: |
Three (3) AC outputs standard,
several optional configurations |
| Output control: |
Only via CB1;
optional remote control panel w/switches available |
| Output receptacles: AC output |
Two (2) NEMA 5-15R and
one (1) AMP CPC standard, various options |
|
MECHANICAL |
| Dimensions (H x D x
W): UPS |
7.0 (4U) x
26 x 19.0 in (178 x
660 x 483 mm) |
| Rack Slide Mount
Patterns: |
General Devices
patterns standard, others optional |
| Alternate Mounting
Options: |
Table, Wall, Floor,
Portable, Horizontal/Vertical |
Unit weight: UPS and
Battery
UPS only
Battery Module only |
112 lb. (51 kg) with lift handles
70 lb. (32 kg) with
lift handles
42 lb. (19 kg) with
lift handle |
| Audible noise: |
Less than 47 dB @
5.0 ft., ANSI "A" scale |
| Cooling type: |
High capacity,
negative pressure, forced air |
| Cooling air
direction: |
Side intake, exhaust to
opposite side, others optional |
| Air intake filter: |
Washable
foam or metal filter media
options |
|
ENVIRONMENTAL |
| Storage temperature: |
-40° to 158° F
ambient (-40° to 70° C) with fully charged batteries with
fully charged batteries |
| Operating
temperature: |
32° to 122°
F ambient ( 0° to 50° C),
-40° to 149° F ambient (
-40° to 65° C)
optional |
| Operating humidity: |
0 to 95% relative
humidity (non-condensing) |
| Storage elevation: |
Up to 40,000 ft
(12,192 m) |
| Operating elevation: |
Up to 15,000 ft
(4,572 m), higher optional |
|
STANDARDS |
| United States: |
ETL Listed to UL-1778
standard for UPS equipment,
MIL STDs 167-1, 454, 810, 901D Grade A, 1399-300A & 2000
|
| Canada: |
CSA C22.2 No. 107
UPS safety requirements |
| EMI Protection: |
EMI/RFI FCC Part 15,
Class A; EN55022; optional MIL STD 461 |
|
OPTIONAL ACCESSORIES |
| |
Emergency Power Off, Alternate I/O Configurations, Dual Source Input, Battery
Expansion, Batteryless Operation,
Battery Charger/Conditioner,
Power Distribution Units, Software Interface, 10BaseT
Ethernet SNMP/HTTP port,
Transport Cases,
Slides and Mounting Kits |